Application: | Construction, Overhead, Underground, Power Station, Overhead Transmission Lines Drop Service Used |
---|---|
Voltage: | Low and Medium Voltage Cable |
Current: | Low Voltage/Mv Voltage/Hv Voltage |
Still deciding? Get samples of US$ 2/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Duplex service drop | |||||||||
Code Name | Phase conductor | Bare Neutral Message | Nominal Weight ( kg/km ) | Allowable Ampacity | |||||
Size & No.of wires | Insulation Thick(mm) | Nominal Diameter (mm) | Size & No.of wires | Rated Strength (kg) | XLPE | Aluminum | ( A ) | ||
Bare | OD | ||||||||
AAC | |||||||||
Pekingese | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 255 | 20.8 | 72.9 | 78 |
Collie | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 255 | 23.8 | 72.9 | 78 |
Cocker | 6-7 | 1.52 | 4.6 | 7.7 | 6-7 | 255 | 32.7 | 72.9 | 78 |
Dachshund | 4-Solid | 1.14 | 5.2 | 7.5 | 6-7 | 400 | 26.8 | 114.6 | 103 |
Spaniel | 4-7 | 1.14 | 5.9 | 8.2 | 6-7 | 400 | 29.8 | 116.1 | 103 |
Cairn | 4-7 | 1.52 | 5.9 | 8.9 | 6-7 | 400 | 40.2 | 116.1 | 103 |
Doberman | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 612 | 38.7 | 184.5 | 136 |
Airedale | 1-19 | 1.52 | 8.4 | 11.5 | 1-7 | - | 56.5 | 233.6 | 158 |
Basset | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 903 | 64 | 294.7 | 182 |
Malemure | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 903 | 64 | 294.7 | 182 |
AAAC | |||||||||
Chihuahua | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 499 | 20.8 | 72.9 | 78 |
VIzsla | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 499 | 23.8 | 72.9 | 78 |
Harrier | 4-Solid | 1.14 | 5.2 | 7.5 | 4-7 | 798 | 26.8 | 116.1 | 103 |
Whippet | 4-7 | 1.14 | 5.9 | 8.2 | 4-7 | 798 | 29.8 | 116.1 | 103 |
Schnauzer | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 1270 | 38.7 | 184.5 | 136 |
Afghan | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 2023 | 64 | 296.1 | 182 |
Hocler | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 2023 | 64 | 296.1 | 182 |
ACSR | |||||||||
Setter | 6-Solid | 1.14 | 4.1 | 6.4 | 6/6/01 | 540 | 20.8 | 72.9 | 78 |
Shepherd | 6-7 | 1.14 | 4.6 | 6.9 | 6/6/01 | 540 | 23.8 | 72.9 | 78 |
Retriever | 6-7 | 1.52 | 4.6 | 7.7 | 6/6/01 | 540 | 32.7 | 72.9 | 78 |
Eskimo | 4-Solid | 1.14 | 5.2 | 7.5 | 4/6/01 | 844 | 26.8 | 114.6 | 103 |
Terrier | 4-7 | 1.14 | 5.9 | 8.2 | 4/6/01 | 844 | 29.8 | 116.1 | 103 |
Yorkshirc | 4-7 | 1.52 | 5.9 | 8.9 | 4/6/01 | 844 | 40.2 | 116.1 | 103 |
Chow | 2-7 | 1.14 | 7.4 | 9.7 | 2/6/01 | 1293 | 38.7 | 184.5 | 136 |
Labrador | 1-19 | 1.52 | 8.4 | 11.5 | 1/6/01 | 1610 | 56.5 | 233.6 | 158 |
Bloodhound | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 |
Bull | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 |
Applications of Duplex ABC cable | To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75°C maximum. |
Applications of Triplex ABC cable | To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation. |
Applications of Quadruplex ABC cable | Used to supply 3 phase power, usually from a polemounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors |