Basic Info.

Model NO.
Bare conductor
Insulation Material
N/M
Sheath Material
N/M
Material Shape
Round Wire
Wire Core Material
Aluminum
Certification
ISO, CCC, BV, SGS
Model
Stranded
Standard
ASTM, BS, IEC, NFC, CSA
Advantages
High Quality, Competitive Price, Fast Response
Core No
7-91
Related Voltage
0.6/1kv, 8.7/15kv, 12-20kv, 21/35kv
Shipment Terms
Fob, CFR, CIF
Export Experience
Southeast Asia, Africa, Middle East
OEM/ODM
Yes
Delivery Time
15-30days
Sample
Free
Transport Package
Wooden Drum, Steel-Wooden Drum or as Requirement
Specification
10mm2-1500mm2
Origin
Henan, China
HS Code
7614900000
Production Capacity
1000 Tons Each Month

Product Description

Applications
AAC are used in overhead power transmission and distribution lines with various grade voltages. Under the same weight,AAC is with higher DC resistance and lower cost than copper conductor. Aluminum is light and is easy to lay.

Overhead Bare Aluminum Conductor All Aluminum Conductor AAC

Standard
 BASTM B231 B232, BS 215 , DIN 48201, CSA C49,NFC 34120


Specification

Stranded 1350 aluminum conductors shown in this section of data are classified, as follows: 
Class AA  For bare conductors usually used in overhead lines.
Class A  For conductors to be covered with weather-resistant materials and for bare conductors where greater flexibility is required.
Class B  For conductors to be insulated with various materials and for conductors indicated under Class A where greater flexibility is required. 
Class C  For conductors where greater flexibility is required

ASTM B231
Code word Size of Conductor Stranding and Wire Diameter Overall Diameter Max.D.C. Resistance at 20°C Code word Size of Conductor Stranding and Wire Diameter Overall Diameter Max.D.C. Resistance at 20°C
AWG or MCM mm mm ohm/km AWG or MCM mm mm ohm/km
Peachbell 6 7/1.554 4.67 2.1692 Verbena 700 37/3.493 24.45 0.0813
Rose 4 7/1.961 5.89 1.3624 Nasturtium 715.5 61/2.75 24.76 0.0795
Lris 2 7/2.474 7.42 0.8577 Violet 715.5 37/3.533 24.74 0.0795
Pansey 1 7/2.776 8.33 0.6801 Cattail 750 61/2.817 25.35 0.0759
Poppy 1/0 7/3.119 9.36 0.539 Petunia 750 37/3.617 25.32 0.0759
Aster 2/0 7/3.503 10.51 0.4276 Lilac 795 61/2.90 26.11 0.0715
Phlox 3/0 7/3.932 11.8 0.339 Arbutus 795 37/3.724 26.06 0.0715
Oxlip 4/0 7/4.417 13.26 0.2688 Snapdragon 900 61/3.086 27.78 0.0632
Valerian 250 19/2.913 14.57 0.2275 Cockscomb 900 37/3.962 27.73 0.0632
Sneezewort 250 7/4.80 14.4 0.2275 Goldenrod 954 61/3.177 28.6 0.0596
Laurel 266.8 19/3.01 15.05 0.2133 Magnolia 954 37/4.079 28.55 0.0596
Daisy 266.8 7/4.96 14.9 0.2133 Camellia 1000 61/3.251 29.36 0.0569
Peony 300 19/3.193 15.97 0.1896 Hawkweed 1000 37/4.176 29.23 0.0569
Tulip 336.4 19/3.381 16.91 0.1691 Larkspur 1033.5 61/3.307 29.76 0.055
Daffodil 350 19/3.447 17.24 0.1625 Bluebell 1033.5 37/4.244 29.72 0.055
Canna 397.5 19/3.673 18.36 0.1431 Marigold 1113 61/3.432 30.89 0.0511
Goldentuft 450 19/3.909 19.55 0.1264 Hawthorn 1192.5 61/3.551 31.05 0.0477
Syringa 477 37/2.882 20.19 0.1193 Narcissus 1272 61/3.668 33.02 0.0477
Cosmos 477 19/4.023 20.12 0.1193 Columbine 1351.5 61/3.78 34.01 0.0421
Hyacinth 500 37/2.951 20.65 0.1138 Carnation 1431 61/3.89 35.03 0.0398
Zinnia 500 19/4.12 20.6 0.1138 Gladiolus 1510.5 61/4.00 35.09 0.0376
Dahlia 556.5 19/4.346 21.73 0.1022 Coreopsis 1590 61/4.099 36.51 0.03568
Mistletoe 556.5 37/3.114 21.79 0.1022 Jessamine 1750 61/4.302 38.72 0.0325
Meadowsweet 600 37/3.233 22.63 0.0948 Cowslip 2000 91/3.76 41.4 0.02866
Orchid 636 37/3.33 23.31 0.0894 Lupine 2500 91/4.21 46.3 0.023
Heuchera 650 37/3.366 23.56 0.0875 Trillium 3000 127/3.90 50.75 0.0192
Flag 700 61/2.72 24.48 0.0813 Bluebonnet 3500 127/4.21 54.8 0.01653

BS215
Code name Nominal aluminum area Stranding and wire diameter Sectional area Overall diameter Linear mass Max. DC resistance at 20ºC Rated strength Final modulus of elasticity Coefficient of linear expansion
  mm2 mm mm2 mm kg/km Ω/km daN hbar /ºC
Midge 22 7/2.06 23.33 6.18 63.8 1.227 399 5900 23.0x10-6
Aphis 25 3/3.35 26.40 7.2 73 1.081 411 5900 23.0x10-6
Gnat 25 7/2.21 26.8 6.6 73 1.066 459 5900 23.0x10-6
Weevil 30 3/3.66 31.6 7.9 86 0.9082 486 5900 23.0x10-6
Mosquito 35 7/2.59 37.0 7.8 101 0.7762 603 5900 23.0x10-6
Ladybird 40 7/2.79 42.8 8.4 117 0.6689 687 5900 23.0x10-6
Ant 50 7/3.10 52.83 9.30 145 0.5419 828 5900 23.0x10-6
Fly 60 7/3.40 63.55 10.20 174 0.4505 990 5900 23.0x10-6
Bluebottle 70 7/3.66 73.7 11.0 202 0.3881 1134 5900 23.0x10-6
Earwig 75 7/3.78 78.5 11.4 215 0.3644 1194 5900 23.0x10-6
Grasshopper 80 7/3.91 84.1 11.7 230 0.3406 1278 5900 23.0x10-6
Clegg 90 7/4.17 95.6 12.5 262 0.2994 1453 5900 23.0x10-6
Wasp 100 7/4.39 106.0 13.17 290 0.2702 1600 5900 23.0x10-6
Beetle 100 19/2.67 106.0 13.4 293 0.2704 1742 5600 23.0x10-6
Bee 125 7/4.90 132.0 14.7 361 0.2169 1944 5600 23.0x10-6
Cricket 150 7/5.36 157.9 16.1 432 0.1818 2385 5600 23.0x10-6
Hornet 150 19/3.25 157.6 16.25 434 0.1825 2570 5600 23.0x10-6
Caterpillar 175 19/3.53 186 17.7 512 0.1547 2863 5600 23.0x10-6
Chafer 200 19/3.78 213.2 18.9 587 0.1349 3240 5600 23.0x10-6
Spider 225 19/3.99 236.9 20.0 652 0.1211 3601 5600 23.0x10-6
Cockroach 250 19/4.22 265.7 21.10 731 0.1083 4040 5600 23.0x10-6
Butterfly 300 19/4.65 322.7 23.25 888 0.08916 4875 5600 23.0x10-6
Moth 350 19/5.00 373.2 25.0 1027 0.07711 5637 5600 23.0x10-6
Drone 350 37/3.58 373.3 25.1 1029 0.07741 5745 5600 23.0x10-6
Locust 400 19/5.36 428.5 26.8 1179 0.06710 6473 5600 23.0x10-6
Centipede 400 37/3.78 415.2 26.46 1145 0.06944 6310 5600 23.0x10-6
Maybug 450 37/4.09 486.9 28.6 1342 0.05931 7401 5600 23.0x10-6
Scorpion 500 37/4.27 529.5 29.9 1460 0.05441 7998 5600 23.0x10-6
Cicada 600 37/4.65 628.6 32.6 1733 0.04588 9495 5600 23.0x10-6
Tarantula 750 37/5.23 794.6 36.6 2191 0.03627 12010 5600 23.0x10-6

DIN 48201
Size Calculated area Stranding and wire diameter Overall diameter Linear mass Rated strength Max. DC resistance at 20ºC
mm2 mm2 mm mm kg/km daN Ω/km
16 15.89 7/1.70 5.1 44 290 1.8018
25 24.25 7/2.10 6.3 67 425 1.1808
35 34.36 7/2.50 7.5 94 585 0.8332
50 49.48 7/3.00 9.0 135 810 0.5786
50 48.36 19/1.80 9.0 133 860 0.5950
70 65.82 19/2.10 10.5 181 1150 0.4371
95 93.27 19/2.50 12.5 256 1595 0.3084
120 117.00 19/2.80 14.0 322 1910 0.2469
150 147.10 37/2.25 15.2 406 2570 0.1960
185 181.60 37/2.50 17.5 501 3105 0.1587
240 242.54 61/2.25 20.2 670 4015 0.1191
300 299.43 61/2.50 22.5 827 4850 0.09650
400 400.14 61/2.89 26.0 1105 6190 0.07221
500 499.83 61/3.23 29.1 1381 7600 0.05781
625 626.20 91/2.96 32.6 1733 9690 0.04625
800 802.10 91/3.35 36.8 2219 12055 0.03611
1000 999.71 91/3.74 41.1 2766 14845 0.02897

IEC 61089
Cross Section Number of Stranding Wires Diameter Linear Mass Rated Strength Max.D.C. Resistance at 20ºC
Wires Conductor
mm2 - mm mm kg/km kN Ω/km
10 7 1.35 4.05 27.4 1.95 2.8633
16 7 1.71 5.12 43.8 3.04 1.7896
25 7 2.13 6.4 68.4 4.5 1.1453
40 7 2.7 8.09 109.4 6.8 0.7158
63 7 3.39 10.2 172.3 10.39 0.4545
100 19 2.59 12.9 274.8 17 0.2877
125 19 2.89 14.5 343.6 21.25 0.2302
160 19 3.27 16.4 439.8 26.4 0.1798
200 19 3.66 18.3 549.7 32 0.1439
250 19 4.09 20.5 687.1 40 0.1151
315 37 3.29 23 867.9 51.97 0.0916
400 37 3.71 26 1102 64 0.0721
450 37 3.94 27.5 1239.8 72 0.0641
500 37 4.15 29 1377.6 80 0.0577
560 37 4.39 30.7 1542.9 89.6 0.0515
630 61 3.63 32.6 1738.3 100.08 0.0458
710 61 3.85 34.6 1959.1 113.6 0.0407
800 61 4.09 36.8 2207.4 128 0.0361
900 61 4.33 39 2483.3 144 0.0321
1000 61 4.57 41.1 2759.2 160 0.0289
1120 91 3.96 43.5 3093.5 179.2 0.0258
1250 91 4.18 46 3452.6 200 0.0231
1400 91 4.43 48.7 3866.9 224 0.0207
1500 91 4.58 50.4 4143.1 240 0.0193

Refered Standards
(1). IEC 61089: Round wire concentric lay overhead electrical stranded conductors
(2). DIN 48 201-5: All Aluminium Conductors
(3). BS 215-1: Aluminium strander conductors
(4). ASTM B231: Stranded Specification for Concentric-Lay-Stranded Aluminium 1350 Conductors
(5). AS 1531: Conductors-Bare overhead-Aluminium and aluminium alloy
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied. 

Bare Conductor Types
(1) all aluminum conductor (AAC)
(2) all aluminum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminum conductor aluminum clad steel reinforced(ACSR/AW)
(6) rear earth aluminum conductor steel reinforced(ACSR/RE)
(7) aluminum conductor aluminum alloy reinforced(ACAR)
(8) aluminum conductor steel supported (ACSS)
(9) aluminum conductor carbon core(ACCC)

About Us

Henan Kingyear Aluminum Industrial Co., Ltd was founded in 2006, located in Gongyi industry area of Henan Province. Our company consists of 3 main subsidiaries, business specialized in develop, manufacture and distribution of Aluminum products. Our factories zone occupies more than 1200,000 square meters and the employees' number has exceeded 200.
We, Kingyear, dedicate ourselves to be a manufacturer of providing comprehensive solutions and customized services to help our customer to solve their problems and improve their profit.
We have a professional sales team with each of them has engaged in this job for 10 years, so that we can provide the comprehensive and professional technology for you.
With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win business relationship!

Our mainly products as follow: 
1--pvc insulated electric wire whatever copper conductor,aluminum conductor, CCA(copper clad aluminum), CCS(copper clad steel).
2--pvc and xlpe insulated power cable with or without armor upto 35kv.
3--rubber cable like welding cable, mine cable, EPR cable and so on.
4--aerial bundled cable(ABC cable) up to 10kv.
5--bare conductor like AAC, AAAC, ACSR, ACAR, ACSR/AW, aluminum clad steel wire, galvanized steel wire, PC steel wire and so on.
Overhead Bare Aluminum Conductor All Aluminum Conductor AAC

Packing & Delivery
Packing Details  : Packing in wooden drum, iron-wooden drum or as customer's requirement.
Delivery Details : 15-25 days after place an order.
Overhead Bare Aluminum Conductor All Aluminum Conductor AAC
Certification
We have obtained CCC, ISO9001, ISO14001 certificates, passed the SGS and BV test.

Our Service:
1.10 years production experience and 10 years export experience .
2.Products certification :ISO,SGS,CE,BV
3.OEM service available based on official & legal authorization.
4.Strict quality control system.
5.Rapid delivery and feedback,Faster lead time than our competitors.
6.Excellent quality with reasonable price.
7.Strong technical support (technical data, drawing, etc.)
8.Professional teamwork service for you actively.
9.Stock available, Free sample is available.
Overhead Bare Aluminum Conductor All Aluminum Conductor AAC

FAQ
Q:I didn't find the cable which I need in this page?
A:If you didn't find the species of cables you need, please contact us directly, we will reply you quickly.
Q:What's your minimum order quantity?
A:It is not so sure, you can confirm it with us. Normally, it will be 1000 meters.
Q:What's your delivery time?
A:It depends on whether we just has the stock for your type.Normally,it takes about 7-15days to achieve production.
Q:How can I get a sample from your company? Is the sample free?
A:If you need the sample to check the quality, please contact us, we will send you the free sample, but the freight charge should be paid.
Q:What if the cable which we need have some differences on specifications from yours?
A: Any difference, we can design and produce according to your requests, which include cable, color, material, processing requirement etc.


Welcome your inquiry! Any question please feel free to contact me as follows:

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier