• 0.6/1kv Cu Conductor PVC Insulation Steel Wire Tape Power Cable
  • 0.6/1kv Cu Conductor PVC Insulation Steel Wire Tape Power Cable
  • 0.6/1kv Cu Conductor PVC Insulation Steel Wire Tape Power Cable
  • 0.6/1kv Cu Conductor PVC Insulation Steel Wire Tape Power Cable
  • 0.6/1kv Cu Conductor PVC Insulation Steel Wire Tape Power Cable

0.6/1kv Cu Conductor PVC Insulation Steel Wire Tape Power Cable

Application: Construction, Overhead, Underground, Industrial, Power Station
Voltage: Low, Medium, High Voltage
Current: AC Cable
Insulation Material: XLPE
Sheath Material: PVC
Material Shape: Round Wire
Samples:
US$ 10/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
power cable
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC
Model
ZRYJV22
Core No
1, 2, 3, 4, 5, 3+1, 4+1, 3+2
Standard
GB/T 12706-2008, IEC 60502-2005
Sheath Color
Black or as Request
Screen
Copper Tape, Copper Wire
Armor Material
Galvanized Steel Wire, Steel Tape, Copper Tape
Popular Size
50mm, 95mm, 120mm, 150mm
Related Voltage
0.6/1kv, 8.7/15kv, 12/20kv, 21-35kv, 36kv
OEM
Yes
Business Type
Factory
Transport Package
Steel-Wooden Drum or as Request
Specification
0.5-800mm2
Origin
Henan, China
HS Code
8544492100
Production Capacity
500km/Month

Product Description

Standard:

IEC60502, BS6346, VDE, AS/NZS, UL, etc 

The Rated Voltage(kv):

1st  class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35 
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 - 26/35

Application:

XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulated cables. XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level. It can be applied in high temperature of 90 degree for a long time.
PVC insulated power cable is suitable for laying fixed in power transmission and distribution lines with A.C. 50HZ and rated voltage of 0.6/1kV.

TYPE

NAME

Main Application

CU core

AL core

YJV/YJY

YJLV/YJLY

XLPE insulated,PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.
Unable to bear external mechanical forces,
but bear the traction force during laid

YJV22/YJV23

YJLV22/YJLV23

XLPE insulated,steel tape armored,
PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.
Able to bear external mechanical forces,
but unable to bear large pulling force

YJV32/YJV33

YJLV32/YJLV33

XLPE insulated,thin steel wire armored,
PVC/PE sheathed power cable

For laying in shaft,water underground will large difference of level.
Able to bear external mechanical forces and moderate pulling force

YJV42/YJV43

YJLV42/YJLV43

XLPE insulated,thick steel wire armored,
PVC/PE sheathed power cable

For laying in water and seabed.
Able to bear positive pressure and pulling force

Number of cores:

1core 2core 3core 3+1core 4core 4+1core 4+2core 5core and so on.

Nominal Section 
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800

Features:

1). XLPE insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical erosion, heat-aging and environmental stress.
2) .Its structures are simple. The long term operating temperature is +90 degrees. It is convenient to use and can be laid with no restriction of different level.
3). Our XLPE cables can be produced according to our specification which is equivalent to IEC 502-1983, and its some indexes are superior to 502-1983.
4). We can design and manufacture special XLPE cable according to the other standards required by the customers.
5).Application: for laying indoor, tunnel, canal and underground. 

Specification
0.6/1kv Cu Conductor PVC Insulation Steel Wire Tape Power Cable

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Alum Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
1x4 2.3 0.7 1 0.8 1.8 10.9
1x6 2.8 0.7 1 0.8 1.8 11.4
1x10 3.6 0.7 1 0.8 1.8 12.2
1x16 4.5 0.7 1 0.8 1.8 13.1
1x25 5.6 0.9 1 0.8 1.8 14.6
1x35 6.7 0.9 1 1.25 1.8 16.6
1x50 8 1 1 1.25 1.8 18.1
1x70 9.4 1.1 1 1.25 1.8 19.7
1x95 11 1.1 1 1.6 1.8 22
1x120 12.4 1.2 1 1.6 1.8 23.6
1x150 13.8 1.4 1 1.6 1.8 25.4
1x185 15.3 1.6 1 1.6 1.8 27.4
1x240 17.5 1.7 1 1.6 1.9 29.9
1x300 19.5 1.8 1 2 2 33.1
1x400 22.6 2 1.2 2 2.2 37.3
1x500 25.2 2.2 1.2 2 2.3 40.5
 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
2x1.5 1.4 0.7 1 0.8 1.8 12.8
2x2.5 1.8 0.7 1 0.8 1.8 13.6
2x4 2.3 0.7 1 0.8 1.8 14.6
2x6 2.8 0.7 1 1.25 1.8 16.5
2x10 3.6 0.7 1 1.25 1.8 18.1
2x16 4.5 0.7 1 1.25 1.8 19.9
2x25 5.6 0.9 1 1.6 1.8 23.6
2x35 6.7 0.9 1 1.6 1.8 25.8
2x50 8 1 1 1.6 1.9 29
2x70 9.4 1.1 1 2 2 .3 3.2
2x95 11 1.1 1.2 2.1 3 7.1
2x120 12.4 1.2 1.2 2 2.3 40.5
2x150 13.8 1.4 1.2 2.5 2.4 45.4
2x185 15.3 1.6 1.4 2.5 20.6 49.9
2x240 17.5 1.7 1.4 2.5 20.7 55.1
2x300 19.5 1.8 1.6 2.5 20.9 60.2
2x400 22.6 2 1.6 2.5 30.1 67.7
 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
3x1.5 1.4 0.7 1 0.8 1.8 13.2
3x2.5 1.8 0.7 1 0.8 1.8 14.1
3x4 2.3 0.7 1 0.8 1.8 15.2
3x6 2.8 0.7 1 1.25 1.8 17.1
3x10 3.6 0.7 1 1.25 1.8 18.9
3x16 4.5 0.7 1 1.25 1.8 20.8
3x25 5.6 0.9 1 1.6 1.8 24.7
3x35 6.7 0.9 1 1.6 1.8 27.2
3x50 8 1 1 1.6 1.9 30.6
3x70 9.4 1.1 1 2 2.1 35.2
3x95 11 1.1 1.2 2 2.2 39.3
3x120 12.4 1.2 1.2 2 2.3 43
3x150 13.8 1.4 1.4 2.5 2.5 48.6
3x185 15.3 1.6 1.4 2.5 2.7 53
3x240 17.5 1.7 1.4 2.5 2.8 58.5
3x300 19.5 1.8 1.6 2.5 3 64
3x400 22.6 2 1.6 3.15 3.3 73.5
 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm mm mm
3x 16/10 4.5 3.6 0.7 0.7 1 1.6 1.8 22.7
3x 25/16 5.6 4.5 0.9 0.7 1 1.6 1.8 26.5
3x 35/16 6.7 4.5 0.9 0.7 1 1.6 1.9 29
3x 50/25 8 5.6 1 0.9 1 1.6 2.1 33
3x 70/35 9.4 6.7 1.1 0.9 1.2 2 2.2 38
3x 95/50 11 8 1.1 1 1.2 2 2.3 42.4
3x120/70 12.4 9.4 1.2 1.1 1.2 2 2.5 48
3x150/70 13.8 9.4 1.4 1.1 1.4 2.5 2.7 52
3x185/95 15.3 11 1.6 1.1 1.4 2.5 2.8 57.2
3x240/120 17.5 12.4 1.7 1.2 1.6 2.5 3.1 64
3x300/150 19.5 13.8 1.8 1.4 1.6 2.5 3.2 69.8
 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
4x1.5 1.4 0.7 1 0.8 1.8 14
4x2.5 1.8 0.7 1 0.8 1.8 14.9
4x4 2.3 0.7 1 1.25 1.8 17
4x6 2.8 0.7 1 1.25 1.8 18.2
4x10 3.6 0.7 1 1.25 1.8 20.2
4x16 4.5 0.7 1 1.6 1.8 23
4x25 5.6 0.9 1 1.6 1.8 26.7
4x35 6.7 0.9 1 1.6 1.9 29.5
4x50 8 1 1 2 2.1 34.2
4x70 9.4 1.1 1.2 2 2.2 38.8
4x95 11 1.1 1.2 2 2.3 42.9
4x120 12.4 1.2 1.4 2.5 2.5 48.6
4x150 13.8 1.4 1.4 2.5 2.7 53.2
4x185 15.3 1.6 1.4 2.5 2.8 58.1
4x240 17.5 1.7 1.6 2.5 3.1 64.8
4x300 19.5 1.8 1.6 2.5 3.2 70.4
4x400 22.6 2 1.8 3.15 3.6 81.3

1). Rated Voltage, No. of Core and Range of Sectional Area

Rated voltage (kv)
Sectional area (mm2)
No. of core
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 - 26/35
1 Core   1.5-800 25-800 25-1200 25-1200 35-1200 50-1200 50-1200 50-1200
2 Core   1.5-185 25-185            
3 Core   1.5-400 25-400 25-400 25-400 35-400 50-400 50-400 50-400
4 Core   2.5-400 25-400            
5 Core   2.5-400 25-400            

 2).  DC resistance: conductor resistance of finished cable at 20ºC per kilometer is not more than the following values.
Nominal section area (mm2) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800
Copper core 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.099 0.0754 0.0601 0.047 0.0366 0.0283 0.0221
Aluminum core 18.1 12.1 7.41 4.61 3.08 1.91 1.2 0.868 0.641 0.443 0.32 0.253 0.206 0.164 0.125 0.1 0.778 0.0605 0.0469 0.0367

 3). Voltage Test and Partial Discharge Test
Rate voltage Uo (kv)
Item
0.6/1 1.8/3 3.6/6 6/6 6/10 8.7/10 8.7/15 12/20 18/20 18/30 21/35 26/35
Voltage Test voltage 3.5 6.5 12.5 21 30.5 42 63 73.5 91
Test time 5 5 5 5 5 5 5 5 5
Partial discharge test Test voltage - - 6.2 10.4 15.1 20.8 31.1 36.3 45
Discharge capacity - - 10 10 10 10 10 10 10

Packaging
Packing Details  : Packing in wooden drum, iron-wooden drum or as customer's requirement.
Delivery Details : 15-25 days after place an order.
0.6/1kv Cu Conductor PVC Insulation Steel Wire Tape Power Cable

About Us
Henan Kingyear Aluminum Industrial Co., Ltd was founded in 2006, located in Gongyi industry area of Henan Province. Our company consists of 3 main subsidiaries, business specialized in develop, manufacture and distribution of Aluminum products. Our factories zone occupies more than 1200,000 square meters and the employees' number has exceeded 200.
We, Kingyear, dedicate ourselves to be a manufacturer of providing comprehensive solutions and customized services to help our customer to solve their problems and improve their profit.
We have a professional sales team with each of them has engaged in this job for 10 years, so that we can provide the comprehensive and professional technology for you.
With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win business relationship!

0.6/1kv Cu Conductor PVC Insulation Steel Wire Tape Power Cable

Our Service:
1.10 years production experience and 10 years export experience .
2.Products certification :ISO,SGS,CE,BV
3.OEM service available based on official & legal authorization.
4.Strict quality control system.
5.Rapid delivery and feedback,Faster lead time than our competitors.
6.Excellent quality with reasonable price.
7.Strong technical support (technical data, drawing, etc.)
8.Professional teamwork service for you actively.
9.Stock available, Free sample is available.

FAQ
Q:I didn't find the product which I need in this page?
A:If you didn't find the species of the produxts you need, please contact us directly, we will reply you quickly.
Q:What's your minimum order quantity?
A:It is not so sure, you can confirm it with us. Normally, it will be 5 tons.
Q:What's your delivery time?
A:It depends on whether we just has the stock for your type.Normally,it takes about 7-15days to achieve production.
Q:How can I get a sample from your company? Is the sample free?
A:If you need the sample to check the quality, please contact us, we will send you the free sample, but the freight charge should be paid.
Q:What if the product which we need have some differences on specifications from yours?
A: Any difference, we can design and produce according to your requests, which include size, color, material, processing requirement etc.


Welcome your inquiry! Any question please feel free to contact me .

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory
Number of Employees
13
Year of Establishment
2018-05-14