YJV XLPE Insulated PVC Sheathed Steel Tape Armoured Armored Electric Power Cable
PRICE INQUIRY
Similar Products:
KINGYEAR Cable is one of the leading cable products production enterprise in China,our mainly products are electric wire,power cable, control cable,bare conductor(AAC/AAAC/ACSR),ABC overhead cable as below.
Structure For Reference (Any of your customized can be accepted)
1 ..... solid (RE) or stranded (RM/SM) bare copper
2 ..... core insulation of polyvinylchloride (PVC)
3 ..... Inner sheath or wrapping tape
4 ..... outer sheath of polyvinylchloride (PVC), black
The technical data of YJV XLPE Insulated PVC Sheathed Steel Tape Armoured Armored Electric Power Cable as below for reference:
MODEL |
NAME |
MAIN APPLICATION |
CU core |
AL core |
|
|
YJV/YJY |
YJLV/YJLY |
(Flame retardant) Cu, Al core XLPE insulated,PVC/PE sheathed power cable |
For laying indoor ,tunnel,canal and underground.Unable to bear external mechanical forces,but bear the traction force during laid |
YJV22/YJV23 |
YJLV22/YJLV23 |
(Flame retardant) Cu, Al core XLPE insulated,steel tape armored,PVC/PE sheathed power cable |
For laying indoor ,tunnel,canal and underground.Able to bear external mechanical forces,but unable to bear large pulling force |
YJV32/YJV33 |
YJLV32/YJLV33 |
(Flame retardant) Cu, Al core XLPE insulated,thin steel wire armored,PVC/PE sheathed power cable |
For laying in shaft,water underground will large difference of level.Able to bear external mechanical forces and moderate pulling force |
YJV42/YJV43 |
YJLV42/YJLV43 |
(Flame retardant) Cu, Al core XLPE insulated,thick steel wire armored,PVC/PE sheathed power cable |
For laying in water and seabed.Able to bear positive pressure and pulling for |
1). Rated Voltage, No. of Core and Range of Sectional Area of this XLPE Insulated PVC Sheathed Steel Tape Armoured Armored Electric Power Cable
Rated voltage (kv)
Sectional area (mm2)
No. of core |
1st class |
0.6/1 |
1.8/3 |
3.6/6 |
6/10 |
8.7/15 |
12/20 |
18/30 |
21/35 |
2nd class |
1/1 |
3/3 |
6/6 |
8.7/10 |
12/15 |
18/20 |
- |
26/35 |
1 Core |
|
1.5-800 |
25-800 |
25-1200 |
25-1200 |
35-1200 |
50-1200 |
50-1200 |
50-1200 |
2 Core |
|
1.5-185 |
25-185 |
|
|
|
|
|
|
3 Core |
|
1.5-400 |
25-400 |
25-400 |
25-400 |
35-400 |
50-400 |
50-400 |
50-400 |
4 Core |
|
2.5-400 |
25-400 |
|
|
|
|
|
|
5 Core |
|
2.5-400 |
25-400 |
|
|
|
|
|
|
2). DC resistance: conductor resistance of XLPE cable at 20ºC per kilometer is not more than the following values.
Nominal section area (mm2) |
1.5 |
2.5 |
4 |
6 |
10 |
16 |
25 |
35 |
50 |
70 |
95 |
120 |
150 |
185 |
240 |
300 |
400 |
500 |
630 |
800 |
Copper core |
12.1 |
7.41 |
4.61 |
3.08 |
1.83 |
1.15 |
0.727 |
0.524 |
0.387 |
0.268 |
0.193 |
0.153 |
0.124 |
0.099 |
0.0754 |
0.0601 |
0.047 |
0.0366 |
0.0283 |
0.0221 |
Aluminum core |
18.1 |
12.1 |
7.41 |
4.61 |
3.08 |
1.91 |
1.2 |
0.868 |
0.641 |
0.443 |
0.32 |
0.253 |
0.206 |
0.164 |
0.125 |
0.1 |
0.778 |
0.0605 |
0.0469 |
0.0367 |
3). Voltage Test and Partial Discharge Test of the XLPE cable
Rate voltage Uo (kv)
Item |
0.6/1 |
1.8/3 |
3.6/6 |
6/6 6/10 |
8.7/10 8.7/15 |
12/20 |
18/20 18/30 |
21/35 |
26/35 |
Voltage |
Test voltage |
3.5 |
6.5 |
12.5 |
21 |
30.5 |
42 |
63 |
73.5 |
91 |
Test time |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
5 |
Partial discharge test |
Test voltage |
- |
- |
6.2 |
10.4 |
15.1 |
20.8 |
31.1 |
36.3 |
45 |
Discharge capacity |
- |
- |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
Applications shown as below:
PVC insulated power cable is suitable for laying fixed in power transmission and distribution lines with A.C. 50HZ and rated voltage of 0.6/1kV.
XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulated cables. XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level. It can be applied in high temperature of 90 degree for a long time.
Kingyear Company Strength:
Customer Visited
After more than 10 years of development, our customers have spread to more than 40 countries and regions around the world, of which more than 50% are old customers.our electric pvc/xlpe power cable, control cable,ABC overhead cable,bare conductor(AAC/AAAC/ACSR) are more favorited by them. We are proud of our good quality-KINGYEAR CABLE.
Cable Packaging Flow:
The packaging of YJV XLPE Insulated PVC Sheathed Steel Tape Armoured Armored Electric Power Cable as below,customized is accepted.
FAQ
Q:I didn't find the cable which I need in this page?
A:If you didn't find the species of cables you need, please contact us directly, we will reply you quickly.
Q:What's your minimum order quantity?
A:It is not so sure, you can confirm it with us. Normally, it will be 1000 meters.
Q:What's your delivery time?
A:It depends on whether we just has the stock for your type.Normally,it takes about 7-15days to achieve production.
Q:How can I get a sample from your company? Is the sample free?
A:If you need the sample to check the quality, please contact us, we will send you the free sample, but the freight charge should be paid.
Q:How to ensure quality ?
A:For any quality problems, we will arrange the technical personnel to solve or return the goods as soon as possible, and bear the corresponding customer losses..
Q:What if the cable which we need have some differences on specifications from yours?
A: Any difference, we can design and produce according to your requests, which include cable, color, material, processing requirement etc.
Why Choose US!
5 Star Customer Reviews
If Any interesting of the ectric wire,electric pvc/xlpe power cable, control cable,bare conductor(AAC/AAAC/ACSR),rubber cable,solar cable,ABC overhead cable can email us freely:
price inquiry !!!
∨∨∨