AAC Aluminum Bare Conductor Hornet 19/3.25mm ASTM IEC DIN BS

Product Details
Type: Bare
Conductor Type: Stranded
Application: Overhead, Overhead Transmission
Still deciding? Get samples of US$ 0/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
17
Year of Establishment
2018-05-14
  • AAC Aluminum Bare Conductor Hornet 19/3.25mm ASTM IEC DIN BS
  • AAC Aluminum Bare Conductor Hornet 19/3.25mm ASTM IEC DIN BS
  • AAC Aluminum Bare Conductor Hornet 19/3.25mm ASTM IEC DIN BS
  • AAC Aluminum Bare Conductor Hornet 19/3.25mm ASTM IEC DIN BS
  • AAC Aluminum Bare Conductor Hornet 19/3.25mm ASTM IEC DIN BS
Find Similar Products

Basic Info.

Model NO.
Bare conductor, aaac conductor cable
Conductor Material
Aluminum
Sheath Material
Bare
Insulation Material
Bare
Material Shape
Round Wire
Range of Application
Overhead Power Transmission Supply
Certification
ISO9001, CE, CCC, RoHS, VDE
Brand
Kingyear
Standard
BS En50182,IEC 61089, ASTM B231,BS 215, DIN 48201
Delivery
7-25days After Received The Prepayment
Hot Sale Countries
Philippine,Yemen,Vietnam, Indonesia,Indonesia
Transport Package
Wooden Drum or Roll, Iron Drum
Specification
25mm, 50mm, 70mm, 90mm, 125mm
Trademark
KINGYEAR
Origin
Henan, China
HS Code
7614900000
Production Capacity
500km/Month

Product Description

AAC Aluminum Bare Conductor Hornet 19/3.25mm ASTM IEC DIN BS
AAC Aluminum Bare Conductor Hornet 19/3.25mm ASTM IEC DIN BS

Applications:
Concentric lay stranded Aluminium Conductor ( AAC) is made up of one or more strands of hard drawn 1350 aluminum alloy. These conductors are used in low, medium and high voltage overhead lines. AAC has seen extensive use in urban areas where spans are usually short but high conductivity us required. The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas. Because of its relatively poor strength to weight ratio, AAC had limited use in transmission lines and rural distribution because of long spans utilized.

The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas.Although aluminium-to-copper connections can be made, it is better to use aluminium conductors for service connections, as various forms of covered cable are available for this purpose.


Advantage:
1. 
high Current Carrying Capacity
2. excellent resistance to corrosion
3Ideal for use in coastal area
4. suitable for low & medium voltage lines in urban area


Standard
ASTM B231, BS215, IEC 61089, DIN 48201, BS EN 50182

The technical data of AAC All Aluminum Alloy Bare Conductor Cable as below for reference,any customized is available.
IEC 61089 
Code Name Nominal No./Nominal
diameter of
wires
Approximate
Overall
Diameter
Approximate
Weight
Nominal
Breaking
Load
Nominal DC
Resistance
at 20°C
mm2 No./mm mm kg/km KN ohm/km
10 10 7/1.35 4.05 27.4 2 2.8633
16 16 7/1.71 5.13 43.8 3 1.7896
25 25 7/2.13 6.39 68.4 4.5 1.1453
40 40 7/2.70 8.1 109.4 6.8 0.7158
63 63 7/3.39 10.17 172.3 10.4 0.4545
100 100 19/2.59 12.95 274.8 17 0.2877
125 125 19/2.89 14.45 343.6 21.3 0.2302
160 160 19/3.27 16.35 439.8 26.4 0.1798
200 200 19/3.66 18.3 549.7 32 0.1439
250 250 19/4.09 20.45 687.1 40 0.1151
315 315 37/3.29 23.03 867.9 52 0.0916
400 400 37/3.71 25.97 1102 64 0.0721
450 450 37/3.94 27.58 1239.8 72 0.0641
500 500 37/4.15 29.05 1377.6 80 0.0577
560 560 37/4.39 30.73 1542.9 89.6 0.0515
630 630 61/3.63 32.67 1738.3 100.8 0.0458
710 710 61/3.85 34.65 1959.1 113.6 0.0407
800 800 61/4.09 36.81 2207.4 128 0.0361
900 900 61/4.33 38.97 2483.3 144 0.0321
1000 1000 61/4.57 41.13 2759.2 160 0.0289
1120 1120 91/3.96 43.56 3093.5 179.2 0.0258
1250 1250 91/4.18 45.98 3452.6 200 0.0231
1400 1400 91/4.43 48.73 3866.9 224 0.0207
1500 1500 91/4.58 50.38 4143.1 240 0.0193
ASTM B231/B 231M
Code Name Nominal
Area 
No./Nominal
diameter of
wires
Approximate
Overall
Diameter
Approximate
Weight
Nominal
Breaking
Load
Nominal DC
Resistance
at 20°C
AWG or MCM mm2 No./mm mm kg/km KN ohm/km
Peachbell 6 13.3 7/1.56 4.68 36.6 2.5 2.1477
Rose 4 21.1 7/1.96 5.88 58.2 3.9 1.3606
Iris 2 33.6 7/2.47 7.41 92.6 6 0.8567
Pansy 1 42.4 7/2.78 8.34 116.6 7.3 0.6763
Poppy 1/0.0 53.5 7/3.12 9.36 147.2 8.8 0.5369
Aster 2/0.0 67.4 7/3.50 10.5 185.7 11.1 0.4267
Phlox 3/0.0 85 7/3.93 11.79 233.9 13.5 0.3384
Oxlip 4/0.0 107.2 7/4.42 13.26 295.2 17 0.2675
Valerian 250 126.7 19/2.91 14.55 348.6 20.7 0.2274
Sneezewort 250 126.7 7/4.80 14.4 348.8 20.1 0.2269
Laurel 266.8 135.2 19/3.01 15.05 372.2 22.1 0.2125
Daisy 266.8 135.2 7/4.96 14.88 372.3 21.4 0.2125
Peony 300 152 19/3.19 15.95 418.3 24.3 0.1892
Tulip 336.4 170.5 19/3.38 16.9 469.5 27.3 0.1686
Daffodil 350 177.3 19/3.45 17.25 487.9 28.4 0.1618
Canna 397.5 201.4 19/3.67 18.35 554.9 31.6 0.143
Goldentuft 450 228 19/3.91 19.55 627.6 35 0.126
Syringa 477 241.7 37/2.88 20.16 664.8 38.6 0.1192
Cosmos 477 241.7 19/4.02 20.1 664.8 37 0.1192
Hyacinth 500 253.3 37/2.95 20.65 696.8 40.5 0.1136
Zinnia 500 253.3 19/4.12 20.6 697.1 38.9 0.1134
Dahlia 556.5 282 19/4.35 21.75 775.8 43.3 0.1018
Mistletoe 556.5 282 37/3.12 21.84 775.7 44.3 0.1016
Meadowsweet 600 304 37/3.23 22.61 836.3 47.5 0.0948
Orchid 636 322.3 37/3.33 23.31 886.9 50.4 0.0892
Heuchera 650 329.4 37/3.37 23.59 907.4 51.7 0.0871
Flag 700 354.7 61/2.72 24.48 975.8 57.1 0.0811
Varbena 700 354.7 37/3.49 24.43 975.7 55.4 0.0812
Nasturtium 715.5 362.6 61/2.75 24.75 998.5 58.4 0.0793
Violet 715.5 362.6 37/3.53 24.71 998.5 56.7 0.0794
Cattail 750 380 61/2.82 25.38 1046 60.3 0.0754
Petunia 750 380 37/3.62 25.34 1046 58.6 0.0755
Lilac 795 402.8 61/2.90 26.1 1110 63.8 0.0713
Arbutus 795 402.8 37/3.72 26.04 1109 61.8 0.0715
BS 215 Part 1
Code name Nominal No./Nominal
diameter of
wires
Sectional Area Overall Weight Calculated Breaking Load Max.D.C. Resistance at 20ºC
mm² No./mm mm² mm kg/km daN Ω/Km
Midge 22 7/2.06 23.33 6.18 64 399 1.227
Aphis 25 3/3.35 26.44 7.22 74 411 1.081
Gnat 25 7/2.21 26.85 6.63 73 459 1.066
Weevil 30 3/3.66 31.56 7.89 86 486 0.9082
Mosquito 35 7/2.59 36.88 7.77 101 603 0.7762
Ladybird 40 7/2.79 42.8 8.37 117 687 0.6689
Ant 50 7/3.10 52.83 9.3 145 828 0.5419
Fly 60 7/3.40 63.55 10.2 174 990 0.4505
Bluebottle 70 7/3.66 73.65 10.98 202 1134 0.3881
Earwig 75 7/3.78 78.55 11.34 215 1194 0.3644
Grasshopper 80 7/3.91 84.05 11.73 230 1278 0.3406
Clegg 90 7/4.17 95.6 12.51 262 1453 0.2994
Wasp 100 7/4.39 106 13.17 290 1600 0.2702
Beetle 100 19/2.67 106.4 13.35 293 1742 0.2704
Bee 125 7/4.90 132 14.7 361 1944 0.2169
Cricket 150 7/5.36 157.9 16.08 432 2385 0.1818
Hornet 150 19/3.25 157.6 16.25 434 2570 0.1825
Caterpillar 175 19/3.53 185.9 17.65 511 2863 0.1547
Chafer 200 19/3.78 213.2 18.9 587 3240 0.1349
Spider 225 19/3.99 237.6 19.95 654 3601 0.1211
Cockroach 250 19/4.22 265.7 21.1 731 4040 0.1083
Butterfly 300 19/4.65 322.7 23.25 888 4875 0.08916
Moth 350 19/5.00 373.1 25 1027 5637 0.07711
Drone 350 37/3.58 372.4 25.06 1027 5745 0.07741
Locust 400 19/5.36 428.7 26.8 1180 6473 0.0671
Centipede 400 37/3.78 415.2 26.46 1145 6310 0.06944
Maybug 450 37/4.09 486.1 28.63 1340 7401 0.05931
Scorpion 500 37/4.27 529.8 29.89 1461 7998 0.05441
Cicada 600 37/4.65 628.3 32.55 1732 9495 0.04588
Tarantula 750 37/5.23 794.9 36.61 2192 12010 0.03627
BS EN 50182
Code
Name
Nominal
Area
No. / Dia.
of Wire
Approx. Overall Diameter  Approx.
Weight
Calculated Breaking Load Max.DC Resistance at 20° C 
mm2 No. / mm mm kg/km kN Ohm/km
Box 18.8 7/1.85 5.55 51.4 5.6 1.748
Acacia 23.8 7/2.08 6.24 64.9 7 1.3828
Almond 30.1 7/2.34 7.02 82.2 8.9 1.0926
Cedar 35.5 7/2.54 7.62 96.8 10.5 0.9273
Deodar 42.2 7/2.77 8.31 115.2 12.4 0.7797
Fir 47.8 7/2.95 8.85 130.6 14.1 0.6875
Hazel 59.9 7/3.30 9.9 163.4 17.7 0.5494
Pine 71.6 7/3.61 10.83 195.6 21.1 0.4591
Holly 84.1 7/3.91 11.73 229.5 24.8 0.3913
Willow 89.7 7/4.04 12.12 245 26.5 0.3665
Oak 118.9 7/4.65 13.95 324.5 35.1 0.2767
Mulberry 150.9 19/3.18 15.9 414.3 44.5 0.2192
Ash 180.7 19/3.48 17.4 496.1 53.3 0.183
Elm 211 19/3.76 18.8 579.2 62.2 0.1568
Poplar 239.4 37/2.87 20.09 659.4 70.6 0.1387
Sycamore 303.2 37/3.23 22.61 835.2 89.4 0.1095
Upas 362.1 37/3.53 24.71 997.5 106.8 0.0917
Yew 479 37/4.06 28.42 1319.6 141.3 0.0693
Totara 498.1 37/4.14 28.98 1372.1 146.9 0.0666
Rubus 586.9 61/3.50 31.5 1622 173.1 0.0567
Sorbus 659.4 61/3.71 33.39 1822.5 194.5 0.0505
Araucaria 821.1 61/4.14 37.26 2269.4 242.2 0.0406
Redwood 996.2 61/4.56 41.04 2753.2 293.9 0.0334


AAC Aluminum Bare Conductor Hornet 19/3.25mm ASTM IEC DIN BS
AAC Aluminum Bare Conductor Hornet 19/3.25mm ASTM IEC DIN BS
AAC Aluminum Bare Conductor Hornet 19/3.25mm ASTM IEC DIN BS
AAC Aluminum Bare Conductor Hornet 19/3.25mm ASTM IEC DIN BS
AAC Aluminum Bare Conductor Hornet 19/3.25mm ASTM IEC DIN BS
AAC Aluminum Bare Conductor Hornet 19/3.25mm ASTM IEC DIN BS
AAC Aluminum Bare Conductor Hornet 19/3.25mm ASTM IEC DIN BS

 

 

AAC Aluminum Bare Conductor Hornet 19/3.25mm ASTM IEC DIN BS
AAC Aluminum Bare Conductor Hornet 19/3.25mm ASTM IEC DIN BS
AAC Aluminum Bare Conductor Hornet 19/3.25mm ASTM IEC DIN BS
AAC Aluminum Bare Conductor Hornet 19/3.25mm ASTM IEC DIN BS

As a leading manufacture in China,Our customers come from around the world,Welcome to visit us at any time!
Just leave your message if you are interested in our products,We will contact you very soon!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier