Canadian Copper Building Wire 600V CSA UL Aluminum 1581 Interlocked Armour

Product Details
Application: Construction, Overhead, Underground, Industrial, Power Station
Voltage: Low Voltage
Current: AC Cable
Still deciding? Get samples of US$ 10/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
17
Year of Establishment
2018-05-14
  • Canadian Copper Building Wire 600V CSA UL Aluminum 1581 Interlocked Armour
  • Canadian Copper Building Wire 600V CSA UL Aluminum 1581 Interlocked Armour
  • Canadian Copper Building Wire 600V CSA UL Aluminum 1581 Interlocked Armour
  • Canadian Copper Building Wire 600V CSA UL Aluminum 1581 Interlocked Armour
  • Canadian Copper Building Wire 600V CSA UL Aluminum 1581 Interlocked Armour
Find Similar Products

Basic Info.

Model NO.
10/3 TECK90
Insulation Material
XLPE
Sheath Material
PVC
Material Shape
Round Wire
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC
Model
Teck 90
Brand
600V, 1kv
Core No
1, 2, 3, 4, 5, 3+1, 4+1, 3+2
Standard
CSA C22.2#131
Sheath Color
Black or as Request
Armor Material
Aluminum Interlocked Armour
Popular Size
12 AWG
Related Voltage
600V, 1000V
OEM
Yes
Business Type
Factory
Transport Package
Steel-Wooden Drum or as Request
Specification
6AWG, up to 1000MCM
Trademark
KINGYEAR
Origin
Henan, China
HS Code
8544492100
Production Capacity
500km/Month

Product Description

10/3 TECK90 Canadian Copper Building Wire 600V CSA UL Aluminum 1581 Interlocked Armour
Canadian Copper Building Wire 600V CSA UL Aluminum 1581 Interlocked Armour

VOLTAGE 1000 V
Optional: 600V 

PRODUCT CONSTRUCTION

  • Insulation:
    • XLPE (RW90 rated) rated: 90°C wet / dry
  • Armour:
    • Aluminum Interlocked Armour (AIA) (standard)
    • Steel Interlocked Armour (SIA) (optional)
  • Jacket:
    • FR LAG PVC (AG14 rated) inner / outer black jacket rated: 90°C to -40°C
  • Available in:
    • Variable Frequency Drive (VFD)
    • Verlock® (for mineshaft applications)
    • Custom colour coding
    • Custom insulation / jacket colours
    • Composite constructions
    • Aluminum conductors

COLOUR CODING

  • 2C Black & white
  • 3C Black, red & blue
  • 4C Black, red, blue & white
  • 5C to 50C Black # coded
NUMBER OF CONDUCTORS CONDUCTOR SIZE (AWG/MCM) GROUND WIRE SIZE (UNINSULATED) (AWG/MCM) OD OVER INNER JACKET (IN/MM) NORMAL DIAMETERS CABLE WEIGHT (LBS/1000FT)/ (KG/KM) AMPACITY (30°C AMBIENT) MAX. PULLING TENSION (PULLING EYE) (LB/KG) MIN. BEND RADIUS (PULL) (IN/MM)
        Over Armour (in/mm) Overall Cable (in/mm)        
2 8 10 0.606 / 15.39 0.846 / 21.49 0.938 / 23.83 409 / 608 55 265 / 120 16.9 / 429
2 6 8 0.744 / 18.9 0.984 / 24.99 1.076 / 27.33 556 / 827 75 419 / 190 19.4 / 492
2 4 8 0.838 / 21.29 1.078 / 27.38 1.17 / 29.72 743 / 1105 95 668 / 303 21.1 / 535
2 3 6 0.932 / 23.67 1.172 / 29.77 1.264 / 32.11 914 / 1361 115 842 / 382 22.8 / 578
2 2 6 0.994 / 25.25 1.234 / 31.34 1.326 / 33.68 1034 / 1539 130 1062 / 482 23.9 / 606
2 1 6 1.152 / 29.26 1.392 / 35.36 1.484 / 37.69 1242 / 1848 145 1339 / 607 26.7 / 678
2 1/0 6 1.232 / 31.29 1.472 / 37.39 1.564 / 39.73 1426 / 2122 170 1690 / 766 28.2 / 715
2 2/0 6 1.318 / 33.48 1.558 / 39.57 1.666 / 42.32 1672 / 2489 195 2130 / 966 30 / 762
3 3/0 4 1.513 / 38.43 1.753 / 44.53 1.861 / 47.27 2634 / 3920 225 4007 / 1818 33.5 / 851
2 4/0 4 1.532 / 38.91 1.837 / 46.66 1.945 / 49.4 2427 / 3611 260 3386 / 1536 35 / 889
2 250 4 1.664 / 42.27 1.969 / 50.01 2.077 / 52.76 2744 / 4084 290 4000 / 1814 37.4 / 950
2 300 4 1.83 / 46.48 2.135 / 54.23 2.243 / 56.97 3250 / 4837 320 4800 / 2177 40.4 / 1025
2 350 3 1.93 / 49.02 2.235 / 56.77 2.343 / 59.51 3668 / 5458 350 5600 / 2540 42.2 / 1071
2 500 3 2.186 / 55.52 2.491 / 63.27 2.623 / 66.62 4843 / 7207 430 8000 / 3629 47.2 / 1199
2 750 2 2.544 / 64.62 2.849 / 72.36 2.981 / 75.72 6710 / 9985 535 12000 / 5443 53.7 / 1363
2 1000 1 2.902 / 73.7 3.207 / 81.5 3.353 / 85.2 8749 / 13012 615 16000 / 7258 40.2 / 1022

*Ampacity value based on Canadian Electrical Code, Version 2018, Table-2.

NUMBER OF CONDUCTORS CONDUCTOR SIZE (AWG/MCM) GROUND WIRE SIZE (UNINSULATED) (AWG/MCM) OD OVER INNER JACKET (IN/MM) NORMAL DIAMETERS CABLE WEIGHT (LBS/1000FT)/ (KG/KM) AMPACITY (30°C AMBIENT) MAX. PULLING TENSION (PULLING EYE) (LB/KG) MIN. BEND RADIUS (PULL) (IN/MM)
        Over Armour (in/mm) Overall Cable (in/mm)        
3 8 10 0.660 / 16.8 0.900 / 22.9 0.992 / 25.2 489 / 727 55 329 / 180 11.9 / 302
3 6 8 0.813 / 20.66 1.053 / 26.76 1.145 / 29.09 729 / 1085 75 629 / 285 20.6 / 524
3 4 8 0.93 / 23.63 1.17 / 29.73 1.262 / 32.06 966 / 1437 95 1002 / 454 22.7 / 577
3 3 6 0.988 / 25.11 1.228 / 31.2 1.32 / 33.54 1133 / 1685 115 1263 / 573 23.8 / 604
3 2 6 1.055 / 26.8 1.295 / 32.9 1.387 / 35.23 1301 / 1936 130 1593 / 723 25 / 634
3 1 6 1.225 / 31.11 1.465 / 37.21 1.557 / 39.55 1583 / 2356 145 2009 / 911 28 / 712
3 1/0 6 1.311 / 33.3 1.551 / 39.39 1.659 / 42.14 1869 / 2781 170 2534 / 1150 29.9 / 758
3 2/0 6 1.403 / 35.65 1.643 / 41.74 1.751 / 44.49 2187 / 3255 195 3194 / 1449 31.5 / 801
3 3/0 4 1.513 / 38.4 1.753 / 44.5 1.861 / 47.3 2602 / 3873 225 4007 / 1818 33.5 / 851
3 4/0 4 1.633 / 41.49 1.938 / 49.24 2.046 / 51.98 3214 / 4783 260 5078 / 2304 36.8 / 936
3 250 4 1.835 / 46.62 2.14 / 54.36 2.248 / 57.11 3790 / 5639 290 6000 / 2722 40.5 / 1028
3 300 4 1.949 / 49.51 2.254 / 57.26 2.362 / 60 4344 / 6464 320 7200 / 3266 42.5 / 1080
3 350 3 2.057 / 52.24 2.362 / 59.99 2.494 / 63.34 4985 / 7419 350 8400 / 3810 44.9 / 1140
3 500 3 2.332 / 59.23 2.637 / 66.98 2.769 / 70.33 6606 / 9830 430 12000 / 5443 49.8 / 1266
3 750 2 2.717 / 69.01 3.022 / 76.75 3.154 / 80.11 9297 / 13835 535 18000 / 8165 56.8 / 1442
3 1000 1 3.097 / 78.7 3.402 / 86.4 3.548 / 90.1 11767 / 17511 615 24000 / 10886 42.6 / 1081
4 8 10 0.719 / 18.26 0.959 / 24.35 1.051 / 26.69 577 / 858 55 529 / 240 18.9 / 480
4 6 8 0.929 / 23.59 1.169 / 29.69 1.261 / 32.03 907 / 1350 75 839 / 380 22.7 / 576
4 4 8 1.045 / 26.6 1.286 / 32.7 1.378 / 35.0 1167 / 1736 76 1336 / 606 24.8 / 630
4 3 6 1.112 / 28.26 1.352 / 34.35 1.444 / 36.69 1380 / 2054 115 1684 / 764 26 / 660
4 2 6 1.189 / 30.21 1.429 / 36.3 1.521 / 38.64 1600 / 2381 130 2124 / 964 27.4 / 696
4 1 6 1.351 / 34.32 1.591 / 40.42 1.699 / 43.16 1982 / 2949 145 2678 / 1215 30.6 / 777
4 1/0 6 1.448 / 36.77 1.688 / 42.87 1.796 / 45.61 2330 / 3467 170 3379 / 1533 32.3 / 821
4 2/0 6 1.551 / 39.4 1.856 / 47.15 1.964 / 49.89 2832 / 4215 195 4259 / 1932 35.4 / 898
4 3/0 4 1.674 / 42.52 1.979 / 50.27 2.087 / 53.01 3407 / 5070 225 5343 / 2423 37.6 / 954
4 4/0 4 1.869 / 47.48 2.174 / 55.22 2.282 / 57.97 4186 / 6229 260 6771 / 3071 41.1 / 1043
4 250 4 2.028 / 51.52 2.333 / 59.26 2.465 / 62.62 4839 / 7201 290 8000 / 3629 44.4 / 1127
4 300 4 2.156 / 54.76 2.461 / 62.51 2.593 / 65.86 5566 / 8283 320 9600 / 4355 46.7 / 1185
4 350 3 2.276 / 57.82 2.581 / 65.57 2.713 / 68.92 6334 / 9426 350 11200 / 5080 48.8 / 1241
4 500 3 2.585 / 65.66 2.89 / 73.4 3.022 / 76.76 8471 / 12606 430 16000 / 7258 54.4 / 1382
4 750 2 3.076 / 78.14 3.381 / 85.89 3.527 / 89.59 11874 / 17671 535 24000 / 10886 63.5/1613

Canadian Copper Building Wire 600V CSA UL Aluminum 1581 Interlocked ArmourOur Service
1.10 years production experience and 10 years export experience .
2.Products certification :ISO,SGS,CE,BV
3.OEM service available based on official & legal authorization.
4.Strict quality control system.
5.Rapid delivery and feedback,Faster lead time than our competitors.
6.Excellent quality with reasonable price.
7.Strong technical support (technical data, drawing, etc.)
8.Professional teamwork service for you actively.
9.Stock available, Free sample is available.

FAQ
Q:I didn't find the product which I need in this page?

A:If you didn't find the species of cables you need, please contact us directly, we will reply you quickly.
Q:What's your minimum order quantity?
A:It is not so sure, you can confirm it with us. Normally, it will be 1000 meters.
Q:What's your delivery time?
A:It depends on whether we just has the stock for your type. Normally,it takes about 7-15days to achieve production.
Q:How can I get a sample from your company? Is the sample free?
A:If you need the sample to check the quality, please contact us, we will send you the free sample, but the freight charge should be paid.
Q:How to ensure quality ?
A:For any quality problems, we will arrange the technical personnel to solve or return the goods as soon as possible, and bear the corresponding customer losses.
Q:What if the cable which we need have some differences on specifications from yours?
A: Any difference, we can design and produce according to your requests, which include cable, color, material, processing requirement etc.
Just leave your message if you are interested in our products, we will contact you very soon!

Canadian Copper Building Wire 600V CSA UL Aluminum 1581 Interlocked Armour

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier