Applications
AAAC Aluminum Alloy Conductor is Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. Aluminum alloy gives higher resistance to corrosion than ACSR.
Standard
BS EN50183,IEC 61089, ASTM B399,BS 3242, DIN 48204,GB/T1179-2008
Specification
Physical contents of aluminum alloy :-
1. Resistivity - 0.0326 Ohms mm2/m at 20°C
2. Density - 2.70 kgm/dm3 at 20°C
3. Coefficient of Linear Expansion - 23 x 10-6 / °C
4. Constant Mass Temperature Coefficient (a) - 0.00360/ °C
5. Material - Heat treated Al. Mg. Si. Alloy
- Approximately 0.5% Mg & 0.5% Si
ASTM B399
Code Name |
Area |
Size & Stranding of ACSR with Equal Diameter |
No. & Diameter of wires |
Overall Diameter |
Weight |
Nominal Breaking Load |
Nominal |
Actual |
MCM |
mm2 |
AWG or MCM |
Al/Steel |
mm |
mm |
kg/km |
kN |
Akron |
30.58 |
15.48 |
6 |
6/1 |
7/1.68 |
5.04 |
42.7 |
4.92 |
Alton |
48.69 |
24.71 |
4 |
6/1 |
7/2.12 |
6.35 |
68.0 |
7.84 |
Ames |
77.47 |
39.22 |
2 |
6/1 |
7/2.67 |
8.02 |
108 |
12.45 |
Azusa |
123.3 |
62.38 |
1/0 |
6/1 |
7/3.37 |
10.11 |
172 |
18.97 |
Anaheim |
155.4 |
78.65 |
2/0 |
6/1 |
7/3.78 |
11.35 |
217 |
23.93 |
Amherst |
195.7 |
99.22 |
3/0 |
6/1 |
7/4.25 |
12.75 |
273 |
30.18 |
Alliance |
246.9 |
125.1 |
4/0 |
6/1 |
7/4.77 |
14.31 |
345 |
38.05 |
Butte |
312.8 |
158.6 |
266.8 |
26/7 |
19/3.26 |
16.30 |
437 |
48.76 |
Canton |
394.5 |
199.9 |
336.4 |
26/7 |
19/3.66 |
18.30 |
551 |
58.91 |
Cairo |
465.4 |
235.8 |
397.5 |
26/7 |
19/3.98 |
19.88 |
650 |
69.48 |
Darien |
559.5 |
283.5 |
477.0 |
26/7 |
19/4.36 |
21.79 |
781 |
83.52 |
Elgin |
652.4 |
330.6 |
556.5 |
26/7 |
19/4.71 |
23.54 |
911 |
97.42 |
Flint |
740.8 |
375.3 |
636.0 |
26/7 |
37/3.59 |
25.16 |
1035 |
108.21 |
Greely |
927.2 |
469.8 |
795.0 |
26/7 |
37/4.02 |
28.14 |
1295 |
135.47 |
IEC 61089
Code Number |
A2 Conductor |
A3 Conductor |
Max.D.C. Resistance of Conductor at 20ºC |
Number of Wires |
Diameter of Wires |
Diameter of Conductor |
Approx. Weight |
Rated Strength |
Number of Wires |
Diameter of Wires |
Diameter of Conductor |
Approx. Weight |
Rated Strength |
mm² |
- |
mm |
mm |
kg/km |
daN |
- |
mm |
mm |
kg/km |
daN |
Ω/km |
16 |
7 |
1.83 |
5.49 |
50.4 |
5.43 |
7 |
1.84 |
5.52 |
50.8 |
6.04 |
1.7896 |
25 |
7 |
2.29 |
6.87 |
78.7 |
8.49 |
7 |
2.30 |
6.9 |
79.5 |
9.44 |
1.1453 |
40 |
7 |
2.89 |
8.67 |
125.9 |
13.58 |
7 |
2.91 |
8.73 |
127.1 |
15.1 |
0.7158 |
63 |
7 |
3.63 |
10.8 |
198.3 |
21.39 |
7 |
3.65 |
10.95 |
200.2 |
23.06 |
0.4545 |
100 |
19 |
2.78 |
13.9 |
316.3 |
33.95 |
19 |
2.79 |
13.95 |
319.3 |
37.76 |
0.2877 |
125 |
19 |
3.10 |
15.5 |
395.4 |
42.44 |
19 |
3.12 |
15.6 |
399.2 |
47.20 |
0.2302 |
160 |
19 |
3.51 |
17.55 |
506.1 |
54.32 |
19 |
3.53 |
17.65 |
511.0 |
58.56 |
0.1798 |
200 |
19 |
3.93 |
19.65 |
623.7 |
67.91 |
19 |
3.95 |
19.75 |
638.7 |
73.20 |
0.1439 |
250 |
19 |
4.39 |
21.95 |
790.8 |
84.68 |
19 |
4.41 |
22.05 |
798.4 |
91.50 |
0.1151 |
315 |
37 |
3.53 |
24.71 |
998.9 |
106.95 |
37 |
3.55 |
24.85 |
1008.4 |
115.29 |
0.0916 |
400 |
37 |
3.98 |
27.86 |
1268.4 |
135.81 |
37 |
4.0 |
28 |
1280.5 |
146.4o |
0.0721 |
450 |
37 |
4.22 |
29.54 |
1426.9 |
152.79 |
37 |
4.24 |
29.68 |
1440.5 |
164.70 |
0.0641 |
500 |
37 |
4.45 |
31.15 |
1585.5 |
169.76 |
37 |
4.47 |
31.29 |
1600.6 |
183.oo |
0.0577 |
560 |
61 |
3.67 |
33.03 |
1778.4 |
190.14 |
61 |
3.69 |
33.21 |
1795.3 |
204.95 |
0.0516 |
630 |
61 |
3.89 |
35.01 |
2000.7 |
213.90 |
61 |
3.91 |
35.19 |
2019.8 |
230.58 |
0.0458 |
710 |
61 |
4.13 |
37.17 |
2254.8 |
241.07 |
61 |
4.15 |
37.35 |
2276.2 |
259.86 |
0.0407 |
800 |
61 |
4.38 |
39.42 |
2540.6 |
271.62 |
61 |
4.4 |
39.6 |
2564.8 |
282.80 |
0.0361 |
900 |
91 |
3.81 |
41.91 |
2861.1 |
305.58 |
91 |
3.83 |
42.13 |
2888.3 |
329.40 |
0.0321 |
1000 |
91 |
4.01 |
44.11 |
3179.0 |
339.53 |
91 |
4.03 |
44.33 |
3209.3 |
366.00 |
0.0289 |
1120 |
91 |
4.25 |
46.75 |
3560.5 |
380.27 |
91 |
4.27 |
46.97 |
3594.4 |
409.92 |
0 0258 |
1250 |
91 |
4.49 |
49.39 |
3973.7 |
424.41 |
|
|
- |
- |
- |
- |
BS EN50183
Code Name |
Calculated Cross Section |
No..Dia.of Wires |
Overall Diameter |
Weight |
Rated Strength |
|
mm² |
No./mm |
mm |
kg/km |
kN |
Box |
18.8 |
7/1.85 |
5.55 |
51.4 |
5.55 |
Acacia |
23.8 |
7/2.08 |
6.24 |
64.9 |
7.02 |
Almond |
30.1 |
7/2.34 |
7.02 |
82.2 |
8.88 |
Cedar |
35.5 |
7/2.54 |
7.62 |
96.8 |
10.46 |
Deodar |
42.2 |
7/2.77 |
8.31 |
115.2 |
12.44 |
Fir |
47.8 |
7/2.95 |
8.85 |
130.6 |
14.11 |
Hazel |
59.9 |
7/3.30 |
9.90 |
163.4 |
17.66 |
Pine |
71.6 |
7/3.61 |
10.8 |
195.6 |
21.14 |
Holly |
84.1 |
7/3.91 |
11.7 |
229.5 |
24.79 |
Willow |
89.7 |
7/4.04 |
12.1 |
245,0 |
26.47 |
Oak |
118.9 |
7/4.65 |
14.0 |
324.5 |
35.07 |
Mulberry |
150.9 |
19/3.18 |
15.9 |
414.3 |
44.52 |
Ash |
180.7 |
19/3.48 |
17.4 |
496.1 |
53.31 |
Elm |
211.0 |
19/3.76 |
18.8 |
579.2 |
62.24 |
Poplar |
239.4 |
37/2.87 |
20.1 |
659.4 |
70.61 |
Sycamore |
303.2 |
37/3.23 |
22.6 |
835.2 |
89.40 |
Upas |
362.1 |
37/3.53 |
24.7 |
997.5 |
106.82 |
Yew |
479.0 |
37/4.06 |
28.4 |
1319.6 |
141.31 |
Totara |
498.1 |
37/4.14 |
29.0 |
1372.1 |
146.93 |
Rubus |
586.9 |
61/3.50 |
31.5 |
1622.0 |
173.13 |
Sorbus |
659.4 |
61/3.71 |
33.4 |
1822.5 |
194.53 |
Araucaria |
821.1 |
61/4.14 |
37.3 |
2269.4 |
242.24 |
Redwood |
996.2 |
61/4.56 |
41.0 |
2753.2 |
293.88 |
Din 48201
Code number |
Calculated area |
Number of wires |
Diameter of wire |
Overall diameter of conductor |
Linear mass |
Rated tensile strength |
Max. DC resistance at 20ºC |
mm2 |
mm2 |
|
mm |
mm |
kg/km |
daN |
Ω/km |
16 |
15.89 |
7 |
1.70 |
5.1 |
43 |
444 |
2.0910 |
25 |
24.25 |
7 |
2.10 |
6.3 |
66 |
677 |
1.3703 |
35 |
34.36 |
7 |
2.50 |
7.5 |
94 |
960 |
0.9669 |
50 |
49.48 |
7 |
3.00 |
9.0 |
135 |
1382 |
0.6714 |
50 |
48.35 |
19 |
1.80 |
9.0 |
133 |
1350 |
0.6905 |
70 |
65.81 |
19 |
2.10 |
10.5 |
181 |
1838 |
0.5073 |
95 |
93.27 |
19 |
2.50 |
12.5 |
256 |
2605 |
0.3579 |
120 |
116.99 |
19 |
2.80 |
14.0 |
322 |
3268 |
0.2854 |
150 |
147.11 |
37 |
2.25 |
15.8 |
406 |
4109 |
0.2274 |
185 |
181.62 |
37 |
2.50 |
17.5 |
500 |
5073 |
0.1842 |
240 |
242.54 |
61 |
2.25 |
20.3 |
670 |
6774 |
0.1383 |
300 |
299.43 |
61 |
2.50 |
22.5 |
827 |
8363 |
0.1120 |
400 |
400.14 |
61 |
2.89 |
26.0 |
1104 |
11176 |
0.0838 |
500 |
499.63 |
61 |
3.23 |
29.1 |
1379 |
13960 |
0.06709 |
625 |
626.20 |
91 |
2.96 |
32.6 |
1732 |
17490 |
0.0540 |
800 |
802.09 |
91 |
3.35 |
36.9 |
2218 |
22402 |
0.0418 |
1000 |
999.71 |
91 |
3.74 |
41.1 |
2767 |
27922 |
0.0335 |
Specification
Stranded 1350 aluminum conductors shown in this section of data are classified, as follows:
Class AA |
For bare conductors usually used in overhead lines. |
Class A |
For conductors to be covered with weather-resistant materials and for bare conductors where greater flexibility is required. |
Class B |
For conductors to be insulated with various materials and for conductors indicated under Class A where greater flexibility is required. |
Class C |
For conductors where greater flexibility is required |
Refered Standards
(1). IEC 61089: Round wire concentric lay overhead electrical stranded conductors
(2). DIN 48 201-5: All Aluminium Conductors
(3). BS 215-1: Aluminium strander conductors
(4). ASTM B231: Stranded Specification for Concentric-Lay-Stranded Aluminium 1350 Conductors
(5). AS 1531: Conductors-Bare overhead-Aluminium and aluminium alloy
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
Bare Conductor Types
(1) all aluminum conductor (AAC)
(2) all aluminum alloy conductor(AAAC)
(3) aluminum conductor steel reinforced (ACSR)
(4) anti-corrosion type ACSR
(5) aluminum conductor aluminum clad steel reinforced(ACSR/AW)
(6) rear earth aluminum conductor steel reinforced(ACSR/RE)
(7) aluminum conductor aluminum alloy reinforced(ACAR)
(8) aluminum conductor steel supported (ACSS)
(9) aluminum conductor carbon core(ACCC)
About Us
Henan Kingyear Aluminum Industrial Co., Ltd was founded in 2006, located in Gongyi industry area of Henan Province. Our company consists of 3 main subsidiaries, business specialized in develop, manufacture and distribution of Aluminum products. Our factories zone occupies more than 1200,000 square meters and the employees' number has exceeded 200.
We, Kingyear, dedicate ourselves to be a manufacturer of providing comprehensive solutions and customized services to help our customer to solve their problems and improve their profit.
We have a professional sales team with each of them has engaged in this job for 10 years, so that we can provide the comprehensive and professional technology for you.
With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win business relationship!
Our mainly products as follow:
1--pvc insulated electric wire whatever copper conductor,aluminum conductor, CCA(copper clad aluminum), CCS(copper clad steel).
2--pvc and xlpe insulated power cable with or without armor upto 35kv.
3--rubber cable like welding cable, mine cable, EPR cable and so on.
4--aerial bundled cable(ABC cable) up to 10kv.
5--bare conductor like AAC, AAAC, ACSR, ACAR, ACSR/AW, aluminum clad steel wire, galvanized steel wire, PC steel wire and so on.
Packing & Delivery
Packing Details : Packing in wooden drum, iron-wooden drum or as customer's requirement.
Delivery Details : 15-25 days after place an order.
Certification
We have obtained CCC, ISO9001, ISO14001 certificates, passed the SGS and BV test.
Our Service
1.10 years production experience and 10 years export experience .
2.Products certification :ISO,SGS,CE,BV
3.OEM service available based on official & legal authorization.
4.Strict quality control system.
5.Rapid delivery and feedback,Faster lead time than our competitors.
6.Excellent quality with reasonable price.
7.Strong technical support (technical data, drawing, etc.)
8.Professional teamwork service for you actively.
9.Stock available, Free sample is available.
Test
FAQ
Q:I didn't find the cable which I need in this page?
A:If you didn't find the species of cables you need, please contact us directly, we will reply you quickly.
Q:What's your minimum order quantity?
A:It is not so sure, you can confirm it with us. Normally, it will be 1000 meters.
Q:What's your delivery time?
A:It depends on whether we just has the stock for your type.Normally,it takes about 7-15days to achieve production.
Q:How can I get a sample from your company? Is the sample free?
A:If you need the sample to check the quality, please contact us, we will send you the free sample, but the freight charge should be paid.
Q:What if the cable which we need have some differences on specifications from yours?
A: Any difference, we can design and produce according to your requests, which include cable, color, material, processing requirement etc.
Welcome your inquiry! Any question please feel free to contact me as follows: