  • 3 Core 4 Core 5 Core 16mm 25mm 35mm 95mm Aluminum/Copper Core PVC/XLPE Underground Power Cable
  • 3 Core 4 Core 5 Core 16mm 25mm 35mm 95mm Aluminum/Copper Core PVC/XLPE Underground Power Cable
  • 3 Core 4 Core 5 Core 16mm 25mm 35mm 95mm Aluminum/Copper Core PVC/XLPE Underground Power Cable
  • 3 Core 4 Core 5 Core 16mm 25mm 35mm 95mm Aluminum/Copper Core PVC/XLPE Underground Power Cable
  • 3 Core 4 Core 5 Core 16mm 25mm 35mm 95mm Aluminum/Copper Core PVC/XLPE Underground Power Cable
Find Similar Products

Basic Info.

Model NO.
Low Volatge Power Cable
Insulation Material
XLPE
Sheath Material
PVC
Material Shape
Round Wire
Wire Core Material
Bare Copper Wire
Certification
CCC, VDE, SGS , BV
Model
YJV
Brand
Kingyear
OEM
Yes
Production Experience
More Than 30years
Delivery
15-20days After Payment
Color
as Per Customer′s Requirement
Transport Package
Export Drum
Specification
70mm, 120mm, 400mm, 95mm
Trademark
Kingyear
Origin
Henan, China
HS Code
8544492100
Production Capacity
3000km/Week

Product Description

3 Core 4 Core 5 Core 16mm 25mm 35mm 95mm Aluminum/Copper Core Steel PVC/XLPE Underground Power Cable

3 Core 4 Core 5 Core 16mm 25mm 35mm 95mm Aluminum/Copper Core PVC/XLPE Underground Power Cable
Applications

TYPE

NAME

Main Application

CU core

AL core

YJV/YJY

YJLV/YJLY

XLPE insulated,PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.
Unable to bear external mechanical forces,
but bear the traction force during laid

YJV22/YJV23

YJLV22/YJLV23

XLPE insulated,steel tape armored,
PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.
Able to bear external mechanical forces,
but unable to bear large pulling force

YJV32/YJV33

YJLV32/YJLV33

XLPE insulated,thin steel wire armored,
PVC/PE sheathed power cable

For laying in shaft,water underground will large difference of level.
Able to bear external mechanical forces and moderate pulling force

YJV42/YJV43

YJLV42/YJLV43

XLPE insulated,thick steel wire armored,
PVC/PE sheathed power cable

For laying in water and seabed.
Able to bear positive pressure and pulling force

XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulated cables.
XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level.It can be applied in high temperature of 90 degree for a long time.

PVC insulated power cable is suitable for laying fixed in power transmission and distribution lines with A.C. 50HZ and rated voltage of 0.6/1kV.



Standard
IEC60502, BS6346, VDE, AS/NZS, UL, etc 



Specification
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Alum Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
1x4 2.3 0.7 1 0.8 1.8 10.9
1x6 2.8 0.7 1 0.8 1.8 11.4
1x10 3.6 0.7 1 0.8 1.8 12.2
1x16 4.5 0.7 1 0.8 1.8 13.1
1x25 5.6 0.9 1 0.8 1.8 14.6
1x35 6.7 0.9 1 1.25 1.8 16.6
1x50 8 1 1 1.25 1.8 18.1
1x70 9.4 1.1 1 1.25 1.8 19.7
1x95 11 1.1 1 1.6 1.8 22
1x120 12.4 1.2 1 1.6 1.8 23.6
1x150 13.8 1.4 1 1.6 1.8 25.4
1x185 15.3 1.6 1 1.6 1.8 27.4
1x240 17.5 1.7 1 1.6 1.9 29.9
1x300 19.5 1.8 1 2 2 33.1
1x400 22.6 2 1.2 2 2.2 37.3
1x500 25.2 2.2 1.2 2 2.3 40.5
 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
2x1.5 1.4 0.7 1 0.8 1.8 12.8
2x2.5 1.8 0.7 1 0.8 1.8 13.6
2x4 2.3 0.7 1 0.8 1.8 14.6
2x6 2.8 0.7 1 1.25 1.8 16.5
2x10 3.6 0.7 1 1.25 1.8 18.1
2x16 4.5 0.7 1 1.25 1.8 19.9
2x25 5.6 0.9 1 1.6 1.8 23.6
2x35 6.7 0.9 1 1.6 1.8 25.8
2x50 8 1 1 1.6 1.9 29
2x70 9.4 1.1 1 2 2 .3 3.2
2x95 11 1.1 1.2 2.1 3 7.1
2x120 12.4 1.2 1.2 2 2.3 40.5
2x150 13.8 1.4 1.2 2.5 2.4 45.4
2x185 15.3 1.6 1.4 2.5 20.6 49.9
2x240 17.5 1.7 1.4 2.5 20.7 55.1
2x300 19.5 1.8 1.6 2.5 20.9 60.2
2x400 22.6 2 1.6 2.5 30.1 67.7
 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
3x1.5 1.4 0.7 1 0.8 1.8 13.2
3x2.5 1.8 0.7 1 0.8 1.8 14.1
3x4 2.3 0.7 1 0.8 1.8 15.2
3x6 2.8 0.7 1 1.25 1.8 17.1
3x10 3.6 0.7 1 1.25 1.8 18.9
3x16 4.5 0.7 1 1.25 1.8 20.8
3x25 5.6 0.9 1 1.6 1.8 24.7
3x35 6.7 0.9 1 1.6 1.8 27.2
3x50 8 1 1 1.6 1.9 30.6
3x70 9.4 1.1 1 2 2.1 35.2
3x95 11 1.1 1.2 2 2.2 39.3
3x120 12.4 1.2 1.2 2 2.3 43
3x150 13.8 1.4 1.4 2.5 2.5 48.6
3x185 15.3 1.6 1.4 2.5 2.7 53
3x240 17.5 1.7 1.4 2.5 2.8 58.5
3x300 19.5 1.8 1.6 2.5 3 64
3x400 22.6 2 1.6 3.15 3.3 73.5
 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm mm mm
3x 16/10 4.5 3.6 0.7 0.7 1 1.6 1.8 22.7
3x 25/16 5.6 4.5 0.9 0.7 1 1.6 1.8 26.5
3x 35/16 6.7 4.5 0.9 0.7 1 1.6 1.9 29
3x 50/25 8 5.6 1 0.9 1 1.6 2.1 33
3x 70/35 9.4 6.7 1.1 0.9 1.2 2 2.2 38
3x 95/50 11 8 1.1 1 1.2 2 2.3 42.4
3x120/70 12.4 9.4 1.2 1.1 1.2 2 2.5 48
3x150/70 13.8 9.4 1.4 1.1 1.4 2.5 2.7 52
3x185/95 15.3 11 1.6 1.1 1.4 2.5 2.8 57.2
3x240/120 17.5 12.4 1.7 1.2 1.6 2.5 3.1 64
3x300/150 19.5 13.8 1.8 1.4 1.6 2.5 3.2 69.8
 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm² mm mm mm mm mm mm
4x1.5 1.4 0.7 1 0.8 1.8 14
4x2.5 1.8 0.7 1 0.8 1.8 14.9
4x4 2.3 0.7 1 1.25 1.8 17
4x6 2.8 0.7 1 1.25 1.8 18.2
4x10 3.6 0.7 1 1.25 1.8 20.2
4x16 4.5 0.7 1 1.6 1.8 23
4x25 5.6 0.9 1 1.6 1.8 26.7
4x35 6.7 0.9 1 1.6 1.9 29.5
4x50 8 1 1 2 2.1 34.2
4x70 9.4 1.1 1.2 2 2.2 38.8
4x95 11 1.1 1.2 2 2.3 42.9
4x120 12.4 1.2 1.4 2.5 2.5 48.6
4x150 13.8 1.4 1.4 2.5 2.7 53.2
4x185 15.3 1.6 1.4 2.5 2.8 58.1
4x240 17.5 1.7 1.6 2.5 3.1 64.8
4x300 19.5 1.8 1.6 2.5 3.2 70.4
4x400 22.6 2 1.8 3.15 3.6 81.3
3 Core 4 Core 5 Core 16mm 25mm 35mm 95mm Aluminum/Copper Core PVC/XLPE Underground Power Cable3 Core 4 Core 5 Core 16mm 25mm 35mm 95mm Aluminum/Copper Core PVC/XLPE Underground Power Cable3 Core 4 Core 5 Core 16mm 25mm 35mm 95mm Aluminum/Copper Core PVC/XLPE Underground Power Cable3 Core 4 Core 5 Core 16mm 25mm 35mm 95mm Aluminum/Copper Core PVC/XLPE Underground Power Cable