• Ahxamk-W 3X240+35 12/20 (24) Kv 3-Core Ahxamk-W
  • Ahxamk-W 3X240+35 12/20 (24) Kv 3-Core Ahxamk-W
  • Ahxamk-W 3X240+35 12/20 (24) Kv 3-Core Ahxamk-W
  • Ahxamk-W 3X240+35 12/20 (24) Kv 3-Core Ahxamk-W
  • Ahxamk-W 3X240+35 12/20 (24) Kv 3-Core Ahxamk-W
  • Ahxamk-W 3X240+35 12/20 (24) Kv 3-Core Ahxamk-W

Ahxamk-W 3X240+35 12/20 (24) Kv 3-Core Ahxamk-W

Application: Construction, Underground, Industrial
Voltage: Low and Medium Voltage Cable
Current: DC & AC
Insulation Material: XLPE
Sheath Material: PVC
Material Shape: Round Wire
Samples:
US$ 0.5/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
AHXAMK-W CABLE
Wire Core Material
Aluminum
Certification
CCC, VDE
OEM
Yes
Production Experience
More Than 30 Years
Transport Package
by Roll or Drum
Specification
3x240+35
Trademark
Kingyear
Origin
Henan
HS Code
8544492100
Production Capacity
100km/Month

Product Description

AHXAMK-W  3X240+35 12/20 (24) kV 3-core AHXAMK-W
 
Ahxamk-W 3X240+35 12/20 (24) Kv 3-Core Ahxamk-W
Ahxamk-W 3X240+35 12/20 (24) Kv 3-Core Ahxamk-W
 
Ahxamk-W 3X240+35 12/20 (24) Kv 3-Core Ahxamk-W
Structure
1 Aluminium, compacted stranded, longitudinally watertight by swelling powder. 
2 Extruded semi conducting conductor screen. 
3 XPLE, dry cured, peroxide crosslinked, nominal thickness 5.5 mm. 
4 Extruded, fully bonded semi conducting insulation screen. 
5 Semi-conducting swelling tape bedding.
6 Screen and moisture barrier of aluminium foil, coated with polyethelene on the outside, longitudinally applied with overlap.
7 Black MDPE composite. Indent marking of sheath: x nkt cables x "Dimesion" AHXAMK-W 24 kV "Year" "Meter" "Code" of aluminium foil, coated with polyethylene on the outside, longitudinally applied with overlap.
8 Copper ground wire.

Application 
Three cable core triplexed together with ground wire. A cable for fixed installation in soil, water and pipes. Suitable for plowing. Made of material for easy recycling.
Technical information 3x50+35 Cu 3x70+35 Cu 3x95+25 Cu 3x95+35 Cu 3x120+35 Cu 3x150+35 Cu 3x185+35 Cu 3x185+50 Cu 3x185+70 Cu 3x240+35 Cu  
Nominal diameter of a sheathed phase conductor mm 27 29 31 31 32 33 35 35 35 38
Nominal cross-sectional area of conductor mm² 50 70 95 95 120 150 185 185 185 240
Nominal diameter of conductor mm 80  95  111  111  126  139  156  156  156  178 
Nominal thickness of conductor screen mm
Nominal thickness of insulation mm 55  55  55  55  55  55  55  55  55  55 
Nominal diameter over the insulation without insulation screen mm 193  207  224  224  234  251  270  270  270  292 
Nominal thickness of insulation screen mm
Nominal diameter of earth conductor mm 69  69  61  69  69  69  69  82  99  69 
Nominal thickness of PE-laminated aluminium foil mm
Nominal thickness of oversheath mm 28  28  29  29  29  29  30  30  30  31 
Nominal cable diameter mm 58,700  61,710  65,790  65,790  67,940  71,490  76,000  76,000  76,000  81,700 
Nominal cable weight kg/km 2,242,541  2,531,084  2,816,938  2,905,244  3,199,835  3,570,126  4,090,594  4,191,058  4,373,059  4,867,559 
Metall weight Cu kg/m 302  302  220  302  302  302  302  410  592  302 
Metall weightAl kg/m 383  545  733  735  953  1,149  1,461  1,458  1,458  1,901 
Maximum forces during installation when pulling by
Max. pulling force by pulling-eye kN 75  105  143  143  180  200  200  200  200  200   
Max. pulling force by pulling-stocking kN 23  32  43  43  54  68  83  83  83  85 
Minimum bending radii
During handling and installation, phase conductor cm 41 44 47 47 48 50 53 53 53 57  
During handling and installation, cable cm 70 74 79 79 82 86 91 91 91 98
In final installation, phase conductor cm 28 30 33 33 34 35 37 37 37 40
In final installation, cable cm 49 52 55 55 57 60 64 64 64 69
Minimum bending radii
During handling and installation, phase conductor m 41  44  47  47  48  50  53  53  53  57   
During handling and installation, cable m 70  74  79  79  81  86  91  91  91  98 
In final installation, phase conductor m 28  30  33  33  34  35  37  37  37  40 
In final installation, cable m 49  52  55  55  57  60  64  64  64  69 
DC resistance
Max. DC resistance of conductor at 20 °C Ω/km 641  443  320  320  253  206  164  164  164  125   
Nominal DC resistance of PE-laminated aluminium foil 20 °C Ω/km 20  19  18  18  17  16  15  15  15 
Technical information 3x50+35 Cu 3x70+35 Cu 3x95+25 Cu 3x95+35 Cu 3x120+35 Cu 3x150+35 Cu 3x185+35 Cu 3x185+50 Cu 3x185+70 Cu 3x240+35 Cu
AC resistance of phase conductor, screen circuit closed
Conductor temperature 40 °C Ω/km 6,927  4,788  3,460  3,460  2,736  2,229  1,776  1,776  1,776  1,356   
Conductor temperature 65 °C Ω/km 7,573  5,234  3,782  3,782  2,991  2,436  1,941  1,941  1,941  1,482 
Conductor temperature 70 °C Ω/km 7,702  5,324  3,846  3,846  3,042  2,478  1,974  1,974  1,974  1,507 
Conductor temperature 90 °C Ω/km 8,219  5,681  4,104  4,104  3,246  2,644  2,106  2,106  2,106  1,607 
Inductance per phase
In flat formation, free space between cables equal to one cable diam 61  59  57  57  55  54  53  53  53  52   
In trefoil formation, cables touching each other mH/km 43  41  39  39  37  36  35  35  35  34 
Electrical values
Calculated operation capacitance µF/km 17  18  20  20  23  24  26  26  26  29   
Calculated charging current with main voltage A/km 10  10  10  11 
Calculated earth fault current with main voltage A/km 18  20  22  22  25  26  29  29  29  32 
Current ratings
Cables in air (25 °C)                    
Flat, conductor 90 °C, open screen A 210 265 320 320 370 425 485 485 485 570
Flat, conductor 90 °C, closed screen A 205 255 310 310 350 395 440 440 440 515
Trefoil, conductor 90 °C, open screen A 195 235 285 285 330 380 430 430 430 505
Trefoil, conductor 90 °C, closed screen A
Cables in the ground (15 °C and 1,0 K.m/W), Installation depth 0,7 m
195 235 280 280 325 370 425 425 425 490
Trefoil, conductor 65 °C, open screen A 155 205 240 240 270 305 345 345 345 395
Trefoil, conductor 65 °C, closed screen A 155 200 235 235 265 300 330 330 330 385
Trefoil, conductor 90 °C, open screen A 185 240 280 280 320 360 405 405 405 465
Trefoil, conductor 90 °C, closed screen A
Maximum thermal short circuit current during 1 s
185 235 275 275 310 355 390 390 390 455
Phase (initial 90 °C, final 250 °C) kA 47  66  89  89  113  141  174  174  174  226 
Metal screen (initial 35 °C, final 250 °C) kA 29  30  32  32  34  36  38  38  38  53 
Metal screen (initial 60 °C, final 250 °C) kA 27  28  29  29  31  33  35  35  35  49 
Metal screen (initial 85 °C, final 250 °C) kA 24  25  27  27  29  30  32  32  32  44 
Bare earth conductor (initial 55 °C, final 200 °C) kA 5 5 36  5 5 5 5 72  10 5
Technical information 3x240+70 Cu 3x300+35 Cu 3x300+70 Cu 3x400+35 Cu 3x400+70 Cu
Nominal diameter of a sheathed phase conductor mm 38 40 40 42 42
Nominal cross-sectional area of conductor mm² 240 300 300 400 400
Nominal diameter of conductor mm 178  198  198  224  224 
Nominal thickness of conductor screen mm
Nominal thickness of insulation mm 55  55  55  55  55 
Nominal diameter over the insulation without insulation screen mm 292  310  310  336  336 
Nominal thickness of insulation screen mm
Nominal diameter of earth conductor mm 99  69  99  69  99 
Nominal thickness of PE-laminated aluminium foil mm
Nominal thickness of oversheath mm 31  32  32  29  29 
Nominal cable diameter mm 81,700  85,890  85,890  90,300  90,300 
Nominal cable weight kg/km 5,173,356  5,602,800  5,892,800  6,208,369  6,498,369 
Metall weight Cu kg/m 592  302  592  302  592 
Metall weightAl kg/m 1,902  2,428  2,428  2,892  2,892 
Maximum forces during installation when pulling by
Max. pulling force by pulling-eye kN 200  200  200  200  200 
Max. pulling force by pulling-stocking kN 85  85  85  85  85 
Minimum bending radii
During handling and installation, phase conductor cm 57 60 60 63 63
During handling and installation, cable cm 98 103 103 108 108
In final installation, phase conductor cm 40 42 42 44 44
In final installation, cable cm 69 72 72 76 76
Minimum bending radii
During handling and installation, phase conductor m 57  60  60  63  63 
During handling and installation, cable m 98  103  103  108  108 
In final installation, phase conductor m 40  42  42  44  44 
In final installation, cable m 69  72  72  76  76 
DC resistance
Max. DC resistance of conductor at 20 °C Ω/km 125  100  100  778  778 
Nominal DC resistance of PE-laminated aluminium foil 20 °C Ω/km 81  81 
  3x240+70 Cu 3x300+35 Cu 3x300+70 Cu  3x400+35 Cu     3x400+70 Cu
AC resistance of phase conductor, screen circuit closed
Conductor temperature 40 °C Ω/km 1,356  1,088  1,088  850  850 
Conductor temperature 65 °C Ω/km 1,482  1,188  1,188  927  927 
Conductor temperature 70 °C Ω/km 1,507  1,208  1,208  943  943 
Conductor temperature 90 °C Ω/km 1,607  1,288  1,288  1,005  1,005 
Inductance per phase
In flat formation, free space between cables equal to one cable diam 52  51  51  49  49 
In trefoil formation, cables touching each other mH/km 34  32  32  31  31 
Electrical values
Calculated operation capacitance µF/km 29  31  31  34  34 
Calculated charging current with main voltage A/km 11  11  11  13  13 
Calculated earth fault current with main voltage A/km 32  34  34  38  38 
Current ratings
Cables in air (25 °C)          
Flat, conductor 90 °C, open screen A 570 650 650 790 790
Flat, conductor 90 °C, closed screen A 515 580 580 680 680
Trefoil, conductor 90 °C, open screen A 505 580 580 695 695
Trefoil, conductor 90 °C, closed screen A
Cables in the ground (15 °C and 1,0 K.m/W), Installation depth 0,7 m
490 565 565 680 680
Trefoil, conductor 65 °C, open screen A 395 445 445 525 525
Trefoil, conductor 65 °C, closed screen A 385 435 435 510 510
Trefoil, conductor 90 °C, open screen A 465 525 525 615 615
Trefoil, conductor 90 °C, closed screen A
Maximum thermal short circuit current during 1 s
455 510 510 600 600
Phase (initial 90 °C, final 250 °C) kA 226  283  283  378  378 
Metal screen (initial 35 °C, final 250 °C) kA 53  57  57  63  63 
Metal screen (initial 60 °C, final 250 °C) kA 49  53  53  58  58 
Metal screen (initial 85 °C, final 250 °C) kA 44  48  48  53  53 
Bare earth conductor (initial 55 °C, final 200 °C) kA 10 5 10 5 10
Production process 
Ahxamk-W 3X240+35 12/20 (24) Kv 3-Core Ahxamk-W

Packaging
Packing Details  : Packing in wooden drum, iron-wooden drum or as customer's requirement.
Delivery Details : 15-25 days after place an order.

Ahxamk-W 3X240+35 12/20 (24) Kv 3-Core Ahxamk-W
About Us 
Henan Kingyear Aluminum Industrial Co., Ltd was founded in 2006, located in Gongyi industry area of Henan Province. Our company consists of 3 main subsidiaries, business specialized in develop, manufacture and distribution of Aluminum products. Our factories zone occupies more than 1200,000 square meters and the employees' number has exceeded 200. We, Kingyear, dedicate ourselves to be a manufacturer of providing comprehensive solutions and customized services to help our customer to solve their problems and improve their profit. We have a professional sales team with each of them has engaged in this job for 10 years, so that we can provide the comprehensive and professional technology for you. With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win business relationship!
Ahxamk-W 3X240+35 12/20 (24) Kv 3-Core Ahxamk-W
Our Service
1.10 years production experience and 10 years export experience .
2.Products certification :ISO,SGS,CE,BV
3.OEM service available based on official & legal authorization.
4.Strict quality control system.
5.Rapid delivery and feedback,Faster lead time than our competitors.
6.Excellent quality with reasonable price.
7.Strong technical support (technical data, drawing, etc.)
8.Professional teamwork service for you actively.
9.Stock available, Free sample is available.

FAQ 
Q:I didn't find the product which I need in this page?
A:If you didn't find the species of the produxts you need, please contact us directly, we will reply you quickly.
Q:What's your minimum order quantity?
A:It is not so sure, you can confirm it with us. Normally, it will be 5 tons.
Q:What's your delivery time?
A:It depends on whether we just has the stock for your type.Normally,it takes about 7-15days to achieve production.
Q:How can I get a sample from your company? Is the sample free?
A:If you need the sample to check the quality, please contact us, we will send you the free sample, but the freight charge should be paid.
Q:What if the product which we need have some differences on specifications from yours?
A: Any difference, we can design and produce according to your requests, which include size, color, material, processing requirement etc.


Just leave your message if you are interested in our products, we will contact you very soon!

Ahxamk-W 3X240+35 12/20 (24) Kv 3-Core Ahxamk-W
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now